ISI Web of Knowledge Take the next step  
Web of Science®
 
Previous Record (inactive) Record 1  of  1 Next Record (inactive)
Record from Web of Science®
PROPOFOL INFUSION DURING REGIONAL ANESTHESIA - SEDATIVE, AMNESTIC, AND ANXIOLYTIC PROPERTIES
Author(s): SMITH I, MONK TG, WHITE PF, DING YF
Source: ANESTHESIA AND ANALGESIA    Volume: 79    Issue: 2    Pages: 313-319    Published: AUG 1994  
Times Cited: 65     References: 18     
Abstract: We examined the plasma concentrations and resultant clinical effects produced by four different propofol bolus infusion regimens in 98 healthy males undergoing elective urologic procedures under regional anesthesia. Patients were randomly assigned to one of four propofol dosage groups. In Groups 1-4, loading doses of propofol equal to 0.2, 0.4, 0.5, or 0.7 mg/kg intravenously, respectively, were followed by fixed-rate propofol infusions of 0.5, 1, 2, or 4 mgkg(-1).h(-1), respectively, during the regional block procedure. Sedation (sleepiness) was assessed independently by the patient and a blinded observer using 100-mm visual analog scales. Intraoperative amnesia was assessed using picture recall. Sedation scores increased in a dose-dependent fashion (13 +/- 19, 21 +/- 19, 45 +/- 28, anp 73 +/- 26 mm at 30 min in Groups 1-4, respectively). Within a given dosage group, sedation scores were stable during the maintenance infusion period. Mean plasma propofol concentrations increased with higher propofol infusion rates (0.16 +/- 0.3, 0.18 +/- 0.1, 0.47 +/- 0.2, and 1.1 +/- 0.8 mu g/mL at 30 min in Groups 1-4, respectively). However, significant variability was observed among individual patient sedation scores and plasma propofol concentrations. Anxiety scores decreased in all four propofol infusion groups during the maintenance period. Hemodynamic variables and hemoglobin oxygen saturation values were similar in all four treatment groups. Recovery from propofol's central effects was rapid after discontinuation of the propofol infusion, and the incidence of side effects was low. Recall of intraoperative events was more commonly observed in the lower-dosage groups (86%, 96%, 58%, and 13% of patients in Groups 1-4, respectively). In conclusion, propofol infusion was an effective sedative technique during regional anesthesia. The sedative effect was highly variable among individuals and could not be predicted from the plasma propofol concentrations. Finally, amnesia was not reliably produced by subhypnotic doses of propofol.
Document Type: Article
Language: English
Addresses:
1. UNIV TEXAS, SW MED CTR, DEPT ANESTHESIOL & PAIN MANAGEMENT, DALLAS, TX 75235 USA
2. WASHINGTON UNIV, SCH MED, DEPT ANESTHESIOL, ST LOUIS, MO 63110 USA
Publisher: WILLIAMS & WILKINS, 351 WEST CAMDEN ST, BALTIMORE, MD 21201-2436
Subject Category: Anesthesiology
IDS Number: NZ337
ISSN: 0003-2999
Previous Record (inactive) Record 1  of  1 Next Record (inactive)